恒压式气体微流量计测量不确定度评估
Uncertainty Evaluation of Constant Pressure Gas Micro-flowmeter
Received:September 27, 2005  Revised:January 10, 2006
HTML  View Full Text  View/Add Comment  Download reader
中文摘要:
      介绍了恒压式气体微流量计的组成和校准原理.在对电容薄膜规做了热流逸效应实验的基础上,对流量计的测量不确定度进行了评估,给出了扩展不确定度和包含因子.通过传递标准漏孔与德国PTB开展了漏率比对,验证了测量不确定度评估结果的可靠性.
英文摘要:
      The structure and calibration theory of a constant pressure gas micro-flowmeter are introduced.On the basis of thermal transpiration effect experiments of capacitance diaphragm gauge(CDG), the uncertainties of constant pressure gas micro-flowmeter are strictly evaluated.And the expanded uncertainties and coverage factors are also given.Through the leak-rate comparison with PTB using standard leak,the reliability of uncertainty evaluation results has been verified.
冯焱  成永军  张涤新
兰州物理研究所,甘肃兰州730000
中文关键词:  恒压  气体微流量计  测量不确定度  评估
英文关键词:constant pressure  gas micro-flowmeter  uncertainty of measurement  evaluation
基金项目:
DOI: