Editor in chief:
Inauguration:
International standard number:ISSN
Unified domestic issue:CN
Domestic postal code:
- Most Read
- Most Cited
- Most Downloaded
LIANG Zhi-guo , SUN Jing-yu , CAO Ying-jie , MIAO Jing-yuan
2006, 26(5):1-6.
Abstract:主要介绍了JJF1152-2006《任意波发生器校准规范》中所采用的校准原则、思想和技术.针对任意波发生器实际校准和应用中需要面对的一系列问题,讨论了任意波发生器的技术内涵和实质;提出了其校准的主导思想:仪器设备的校准、波形生成能力的校准、波形生成质量的校准;确定了校准的主要内容:仪器设备极限参数的校准和失真特性的校准;介绍了任意波发生器校准所采取的技术措施:虚拟仪器模式下的模型化测量方法;讨论了校准仪器设备选取原则:通用性原则、溯源性原则和最简捷原则和高精度原则.针对主要校准项目参数,讨论了几种典型校准方法的优缺点.
ZHANG Ji-yun , JIANG Min-zhong , QIU Chong-tao , WANG Xin-xing , GUAN Shao-bin
2006, 26(5):7-9.
Abstract:This paper introduces the methods and the results of determining the air kerma rate at different heights above the central point on the surface of radiactivity body source used by the experimental measurement methods and the Monte Carlo theoretical analog computation method.The results of this study show that the certifications of both the experimental measurements and the theoretical analog computation have a better consistency and have no distinctive systematic difference.Based on the above results,the reduction coefficient of Becquerel method is fitted in the first time,which can reflect objectively the air kerma rate per radionuclide concentration unit above China's body source standard for environmental ionizing radiation.So the accuracy of the air kerma rate above pad body source by Becquerel method is improved.
WAN Wen-jing , CHENG Yong-mei , YANG Yang
2006, 26(5):10-13.
Abstract:In this paper, a moving target tracking method based on moment character and feature-optical-flow is proposed. The corner feature is firstly extracted for object matching, the matching strategy refers to Hu moment local matching method, then, a new feature-optical-flow clustering algorithm is presented to finish the clustering of two objects. Simulation results show that this method can improve the tacking accuracy while decreasing the computational burden. It also overcomes the track-lost problem when the object has a little deflexion.
2006, 26(5):14-16.
Abstract:This paper introduces the methods of digital sampling, relative analysis, frequency spectrum analysis, combining the shearing intensity experiment of composite. The material function and analysis result are verified, and the choice of the analytical parameter is studied. This paper makes a beneficial research in the shearing intensity of composite.
XU Zi-fu , RUAN An-lu , HAN Wei , ZHENG Yun-fei
2006, 26(5):17-18.
Abstract:A nwe type platform based on laser is introduced in the paper.The light platform can balance automatically in the certain range by the technology of gravitation pendulum.The platform can beam the light and form the horizontal light datum plane and the vertical light datum plane,which are orthogonal each other.With the horizontal rolling framework and the bracket,the horizontal light datum plane can be moved up and down and right and left freely and the characters of output light signal can be kept at the same time.
ZOU Jiu-gui , GAN Jun-hong , JI Guo-ding
2006, 26(5):19-20,26.
Abstract:介绍了一种高精度二维自准直仪,它采用面阵CCD器件作为光电传感器,利用自准直原理实现了二维角度的测量,其测量范围为±300",精度为±0.2".
2006, 26(5):21-23.
Abstract:A half bridge switching mode power supply(SMPS) based on PWM technology is introduced.The detailed design method of high frequency transformer,PWM control and drive circuit is provided.A 150W half bridge SMPS using this method is designed.At last,the experimental waveforms are presented.
ZHENG Jian-xiang , QIN Hai-feng , WU Jian-hong
2006, 26(5):24-26.
Abstract:The article introduces a design plan of the automatic control system of the force standard machine.The system uses a series of techniques,such as STD industry bus,8051 SCM and photoeletric detection,it can automatic load or unload,record and process the data,print the inspection certificate etc.
CHEN Jian-ping , HUANG Ling-zhi
2006, 26(5):27-29.
Abstract:The design and structure of nitrogen tetroxide concentration monitor are introduced. Some key points are resolved with advanced software design conception and technology, and a nitrogen tetroxide concentration monitor with sound and light alarm is developed.
LI Jun , XIE Lian-song , CHEN Li
2006, 26(5):30-32,52.
Abstract:This paper presents the constitution of radar liquid level measurement system in aircraft fuel system and its application in data acquisition and processing of aircraft fuel system. The developing direction of this advanced system is disserted.
2006, 26(5):33-35,60.
Abstract:We describe a system for measuring the nonlinearity of optical fiber power meter over a wide power dynamic range, and the system uses optical components all. The system also measures the discontinuities between neighboring power ranges. The measurement data are provided and the uncertainty of measurement result is discussed.
2006, 26(5):36-38.
Abstract:The structure, make up and operational principle of the vertical impact machine are intruduced. The calibrating system and calibrating method in accordance with separate technical specifications are set up, employing the computer to collect data and analyze the waves in the whole calibrating process. And the corresponding calibrating method for each test sample is adjusted according to the different test piece.
NIU Yu-mei , ZHAO Shou-guo , WANG Ji-gang , LI Hong-xia
2006, 26(5):39-41.
Abstract:The method of determining the nitrotrobenzene in the water of Dalian River is introduced in this paper. The result is also analyzed.
2006, 26(5):42-43,55.
Abstract:Three digital verifying methods of DC resistance are introduced in this methods are analyzed and the uncertainty of measurement is given. The selected methods the DC resistance are given.
2006, 26(5):44-46.
Abstract:In order to determine the accuracy of the temperature sensor's radiation correction calibration,the comparison of the calibration results of temperature sensors conducted by different units need to be done.In this article,the comparative study of the temperature sensor and uncertainty analysis are introduced.
LV Guo-yi , HAN Yi-zhong , CHEN Guang
2006, 26(5):47-49.
Abstract:This paper mainly introduces the new character, function, design and use of system software of collecting the data of temperature and humidity on site testing.
LIU Yan , LI Dong-mei , ZHOU Da-qian
2006, 26(5):50-52.
Abstract:The basic request and the establishment process of the metrological confirmation system are analyzed and sum up in this paper.
Editor in chief:
Inauguration:
International standard number:ISSN
Unified domestic issue:CN
Domestic postal code: