Editor in chief:
Inauguration:
International standard number:ISSN
Unified domestic issue:CN
Domestic postal code:
- Most Read
- Most Cited
- Most Downloaded
Chen Qiu , Chen Ming , Fan Dongyuan
1999(6):3-6.
Abstract:Eliminating the effect of shell vibration is the key technique for a Coriolis-type massflowmeter with a single straight measuring tube. A compensating tube stimulate independently, contro1led under given condition, will balance the force produced by the measuring tube. The shellvibration will be reduced. The design demand and the stimulate control conditions of the compensatingtube are discussed. The results are verified by experiment.
Zhou Weihu , Ding Xiaomu , Zhang Yuwen
1999(6):7-9.
Abstract:This paper summarizes the two standards used for the calibration of theodolites,presents a guideline and methods for the calibration of theodolite standards thems elves, especially forthe calibration of standard stability.
Xu Yuchun , Zhao Wansheng , Zhao Jiaqi , Liu Jinchun
1999(6):10-12.
Abstract:This paper introduces the present state of the measurement technique of slender neck ofthe precision e1astic components at home and analyzes the existential problems of the present measuringmethod. Then the inductance measuring method has been suggested and the relative measuringequipment has been developed,so the on-line measurement of the slender neck of the precision elasticcomponents can be realized.
1999(6):13-15.
Abstract:TimeConstantMeasuringSystemofInfraredProbe(2)GaoYesheng(上接1999年第19卷第5期第12页)1.2关键技术的解决1.2.回脉冲响应法的关键是脉冲光源的获得和数据的采集处理为获得1~3μm,3~5μm,8~14μm三波段的超短单脉冲光,光源系统采用了激光镇模、受激氢拉曼、光参量、单脉冲提取技术。1)腔内单脉冲的提取由于本激光系统振荡级腔长为1m,锁模序列脉冲的间隔约为6.6ns,这样被测量的探测器的时间常数大于6.6ns时,将产生很大的测量误差,为此,采用了腔内提取单脉冲的方法,以获得单脉冲光输出;且该方法比月球吸法腔外…
Sun Yujiu , Wang Lin , Chen Zhizhong
1999(6):16-18.
Abstract:The uncertainty analysis method of standard ring gauge is introduced in this paper. It contributes to the realization of "Verification Regulation JJG894-95 of Standard Ring Gauge" and theimplementation of uncertainty of measurement as well.
1999(6):19-22.
Abstract:As the software platform of CAT work station, the application of Visual Automated Test Environment (VATE) has inestimable effect on heightening the developing efficiency of the testing software and fully using the PC resource in measuing system- This paper introduces a method ofdeveloping the testing software automatic generation environment on the Microsoft Windows platform.That is through setting up the instrument driver database and using constructural process design idea torelialize the testing software generation.
1999(6):23-26,29.
Abstract:Owing to the IMP S-net interface on the S-network exists a defect upon itself in thecircuit,the communication between IMP and host computer will be baffied frequently. In this paper,theIMP S-net interface is improved on the circuit,thus the communication can be stable and reliable.
Huang Qingcheng , Ye Dong , Liu Dejun , Che Rensheng
1999(6):27-29.
Abstract:As the inevitable outcome of combining the virtual rea1ity technique with coordinate measuring technique,the virtual coordinate measuring machine is the need for developing the virtual manufacture technology. This paper proposes a new developing orientation of 3D CMM-virtual coordinate measuring machine (VCMM), introduces the system structure and basic function of theVCMM and the necessary software and hardware environment for the simulation of VCMM.
Li Junqiang , Xiong Changyou , Li Taijing , Jiao Renmin
1999(6):30-33,41.
Abstract:An automatic circle grating dynamic testing instrument with high accuracy is presented in this paper- The expending uncertainty during dynamic measurement of circle grating is O. O8". A high rotation precision air static pressure bearing and multiprobe homogenization technique are adopted tothe instrument for decreasing the effect of the error of the reference ruled grating disc- In the meantime,the computer system is adopted to control the measuring process and process the data, thereby theautomatic measurement is realized. The result of test and measurement and the error curve are printedby the printer.
1999(6):34-35,45.
Abstract:This paper introduces three kinds of data acquisition systems and compares theirperformances.
1999(6):36-37.
Abstract:This paper describes some problems met during the upgrade of applicable software ofinformation managing system of aviation metrology,their solving methods and the effect after upgrade.
1999(6):38-41.
Abstract:The dynamic characteristic of quartz linear extensional-mode oscillator has beenanalyzed theoritically and various damps affecting quality of the quartz oscilator under near field havebeen discussed. The obtained analytic model has been compared with the experiment result.
1999(6):42-43.
Abstract:Regarding with the problem of selecting electrical measuring instrument in thermocouplecalibration fields,we general1y analyze the error of high precision digital voltmeter (DVM) and providethe technicians the reference of selecting measuring instruments in accordance with the verificationregulations