Abstract:In order to study the mathematical model of Venturi flowmeter under transient flow, the flow field of Venturi flowmeter under step flow was simulated by FLUENT software. The discrete values of flow and differential pressure under different step flow conditions were obtained. The coefficients of differential equation were obtained by plane fitting method, and then the mathematical model of Venturi flowmeter under transient flow was determined.