Discussion on the Influence of Different Temperature Detectors and Filling Medium on the Temperature Measurement of Dry Block Digesters
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    This paper uses different temperature detectors and filling medium to do the temperature experiment of a dry block digester, and discusses the influence of the temperature measurement results in different conditions. The experiment results show that it is recommended to use thermocouple temperature detectors for temperature measurement. Meanwhile the filling medium can be used as the auxiliary heat conduction to reduce the temperature error caused by non-tight contact.