Abstract:A new calibration method of the six-port measurement system is proposed.The self-calibration equation of the six-port reflectometer is derived from the six-port relative power theory.A new method of finding initial estimation needed for the iteractive method is discussed.The system equations are solved by the grads method.The simulation result shows that a matched load and four unmatched loads are needed for the self-calibration.