Abstract:The authors present a novel detecting method of Liner Variable Differential Transformer Self-monitoring signal. Based on that, by a technology of time division multiplexing, the circuit using one chip of universal LVDT signal conditioner that can simultaneously process the output signal and the monitoring signal is designed. Experiments upon the linearity and fault detecting capacity of the circuit are performed and the results are analyzed.